重庆体彩

重庆体彩Welcome to Hebei Chenyu waterproof building materials Co., Ltd.

中文 | ENG  官方微信

CYU-F505 Planting Roofing Root Piercing Waterproofing membrane

  • Detail
  • Specifications
  • Construction Technology
    1. Has excellent waterproof function, can form a high-strength waterproof layer, resistance to pressure water capacity, long to maintain waterproof effect;
    With tissue plant with the penetration function, not only can bear the plant root puncture, does not affect the normal growth of plants;
    High tensile strength, corrosion resistance, resistance to mold, excellent weather resistance;
    Excellent resistance to high and low temperature performance, the grass-roots shrinkage deformation and cracking adaptability, hot and cold areas are applicable;
    Hot melt construction, easy construction and reliable and reliable heat seam.
     
    Used for planting roofs, roof gardens, garage roofs and roofs and roofs requiring greening.
     
    Plastic tape is packed in rolls
     
    Storage and transportation were stacked, to avoid rain, exposure, storage temperature is not higher than 50 ℃;
    Storage should be placed when the membrane is not more than two layers, to prevent the cut or transverse pressure, to avoid and easy to send
         Biochemical reaction of the medium contact.
    序号 项目 指标
    1 Soluble matter Coment g/㎡≥ 2900
    2 Heat resistance 105
    ≤mm 2
    appearance No Sliding , following,dripping
    3 Low temperature flexibility/℃ -25
    4 Impermeability 30min 0.3MPa
    5 TENSION/(N/50mm)≥ 800
    6 Wlongation at maximum tension/%≥ 40
    7 Resistance to root puncture performance pass
    8 Corrosion resistance to mold Mildew grade 0 grade或1grade
    Rally retention rate%≥ 80
    9 Dimensional change rate%≤ 1.0

    Planting system structure layer generally have vegetation layer, planting soil, filter layer, storage and drainage layer, root-puncture waterproof layer, the general way layer, leveling layer, insulation layer, find slope layer, structure layer and so on.
     
    Structure: to be cast-in-place reinforced concrete, roof slope greater than 15% should take anti-slip measures, roof slope greater than 50% should not be planted;
    Find slope layer: the roof slope should be 2%, slope length of 4m with cement mortar to find the slope, the slope is too long when the proposed structure to find slope;
    Insulation layer: planting soil thickness greater than 80mm, do not do insulation layer;
    Leveling layer: should choose 20 thick 1: 3 cement mortar for leveling treatment;
    Ordinary waterproof side: not only the use of root-resistant puncture waterproof layer in the lower part of the laying of the membrane or coating;
    Resistant root puncture layer: in the ordinary waterproof layer above the selection of root puncture waterproofing membrane again laying;
    Storage and drainage layer: the use of concave and convex drainage board, mesh intertwined drainage board or particle size less than 25mm light ceramic, play a drainage, water storage;
    Filter layer: 250g / ㎡ non-woven fabrics, mineral wool pad and other materials play a role in water retention and water treatment, joints should be used line suture;
    Planting soil: roof planting soil should choose improved soil or compound planting soil, basement roof roof planting should use pastoral soil.