重庆体彩

Welcome to Hebei Chenyu waterproof building materials Co., Ltd.

中文 | ENG  官方微信

CYW-T604 metal roofing waterproof coating

  • Detail
  • Specifications
  • Construction Technology
    Features
    1, low-odor water-based paint, no harm to human health and the environment, green.
    2, good adhesion, do not fall off, anti-UV, anti-skin injury
    3, has a strong anti-acid and alkali capacity, can inhibit the growth of mold and algae.
    4, easy to build and clean.
    5, the coating has a good permeability, breathing effect, can not afford to drum
     
    The scope of application
    Mainly used for steel structure of the roof of the plant, the wall of the joint seam waterproofing, steel ship deck, steel platform and other base surface waterproof. Metal roofs generally need to do the following areas of water treatment, horizontal lap, vertical lap, fan mouth, out of the roof pipe, air conditioning pipes, lighting panels around, roof, gutter, metal plate and parapet junction, screw firmware Metal roof waterproofing weak links.
     
    Storage and transportation
    1, the product placed in a clean, dry, sealed plastic bucket.
    2, transport by non-dangerous goods requirements, transport, to prevent rain, exposure, extrusion, collision, inverted, keep the packaging intact.
    3, the product should be stored in a ventilated, dry, cool place, to prevent direct sunlight. Storage temperature of not less than 5 ℃, must not be less than 0 ℃.
    Construction method
    1, first according to the site waterproof location and size of the choice of polyester cloth width.
    2, in the need to deal with the area coated with a layer of flexible waterproof coating, when it is still wet, the polyester cloth directly on it, with its brush to ensure that polyester cloth is not blistering, no wrinkles , And then brush a layer of the bottom of the paint, fully impregnated polyester cloth, so that the entire brushing layer full of Fu paste, and so on the second layer of paint dry, brush a layer of surface insulation coating. According to the construction process to do the first part of the rivets, and then do a large area of ??construction, and then repair the complex interface.
    3, all brushing parts of the inspection, if the construction defects to be repaired.
     
    Precautions
    1, waterproof coating construction of the ambient temperature shall not be less than 5 ℃, as expected in the paint dry time 12 hours of rain, snow or dew in the evening when the afternoon after 3 pm are not construction.
    2, paint open the bucket, the need to stir evenly.
    3, the main application of the application of brushing method (with paint brush), brushing evenly, each coating should not be too thick.
    4, the paint must be equipped with polyamide cloth, usually using a three-way cloth.
    5, the coating curing process, should not let people move around, is strictly prohibited in the cured coating on the dragging heavy objects to prevent damage to the waterproof layer, often the roof of the man, in the waterproof construction 24 hours after the master.
    6, open the lid after the paint to use as soon as possible, not used to complete the paint to seal, so as not to change the nature.